Skip to main navigation Skip to search Skip to main content

A self-referencing glutamate biosensor for measuring real time neuronal glutamate flux

  • E. S. McLamore
  • , S. Mohanty
  • , J. Shi
  • , J. Claussen
  • , S. S. Jedlicka
  • , J. L. Rickus
  • , D. M. Porterfield

Research output: Contribution to journal › Article › peer-review

Abstract

Quantification of neurotransmitter transport dynamics is hindered by a lack of sufficient tools to directly monitor bioactive flux under physiological conditions. Traditional techniques for studying neurotransmitter release/uptake require inferences from non-selective electrical recordings, are invasive/destructive, and/or suffer from poor temporal resolution. Recent advances in electrochemical biosensors have enhanced in vitro and in vivo detection of neurotransmitter concentration under physiological/pathophysiological conditions. The use of enzymatic biosensors with performance enhancing materials (e.g., carbon nanotubes) has been a major focus for many of these advances. However, these techniques are not used as mainstream neuroscience research tools, due to relatively low sensitivity, excessive drift/noise, low signal-to-noise ratio, and inability to quantify rapid neurochemical kinetics during synaptic transmission. A sensing technique known as self-referencing overcomes many of these problems, and allows non-invasive quantification of biophysical transport. This work presents a self-referencing CNT modified glutamate oxidase biosensor for monitoring glutamate flux near neural/neuronal cells. Concentration of basal glutamate was similar to other in vivo and in vitro measurements. The biosensor was used in self-referencing (oscillating) mode to measure net glutamate flux near neural cells during electrical stimulation. Prior to stimulation, the average influx was 33.9±6.4fmolcm-2s-1). Glutamate efflux took place immediately following stimulation, and was always followed by uptake in the 50-150fmolcm-2s-1 range. Uptake was inhibited using threo-β-benzyloxyaspartate, and average surface flux in replicate cells (1.1±7.4fmolcm-2s-1) was significantly lower than uninhibited cells. The technique is extremely valuable for studying neuropathological conditions related to neurotransmission under dynamic physiological conditions.

Original languageEnglish (US)
Pages (from-to)14-22
Number of pages9
JournalJournal of Neuroscience Methods
Volume189
Issue number1
DOIs
StatePublished - May 2010
Externally publishedYes

Keywords

  • Biosensor
  • Flux
  • Glutamate
  • Self-referencing
  • Transport

ASJC Scopus subject areas

  • General Neuroscience

Fingerprint

Dive into the research topics of 'A self-referencing glutamate biosensor for measuring real time neuronal glutamate flux'. Together they form a unique fingerprint.

Cite this