TY - JOUR
T1 - A SOCP-Based ACOPF for Operational Scheduling of Three-Phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters
AU - He, Mingyue
AU - Soltani, Zahra
AU - Ghaljehei, Mohammad
AU - Esmaili, Masoud
AU - Ma, Shanshan
AU - Chen, Mengxi
AU - Khorsand, Mojdeh
AU - Ayyanar, Raja
AU - Vittal, Vijay
N1 - Publisher Copyright: © 1969-2012 IEEE.
PY - 2024/1/1
Y1 - 2024/1/1
N2 - The proliferation of distributed energy resources (DERs) imposes new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution networks, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. Moreover, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effectiveness of the proposed ACOPF for unbalanced systems in providing an optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simulations show that the optimal settings cause no stability issue for the distribution system.
AB - The proliferation of distributed energy resources (DERs) imposes new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution networks, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. Moreover, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effectiveness of the proposed ACOPF for unbalanced systems in providing an optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simulations show that the optimal settings cause no stability issue for the distribution system.
KW - AC optimal power flow
KW - Volt-Var controller
KW - distributed energy resources
KW - second-order cone programming
KW - three-phase unbalanced distribution system
UR - http://www.scopus.com/inward/record.url?scp=85147279220&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85147279220&partnerID=8YFLogxK
U2 - 10.1109/TPWRS.2023.3236881
DO - 10.1109/TPWRS.2023.3236881
M3 - Article
SN - 0885-8950
VL - 39
SP - 229
EP - 244
JO - IEEE Transactions on Power Systems
JF - IEEE Transactions on Power Systems
IS - 1
ER -