TY - JOUR
T1 - Analysis of backwash settings to maximize net water production in an engineering-scale ultrafiltration system for water reuse
AU - Alhussaini, Mohammed A.
AU - Binger, Zachary M.
AU - Souza-Chaves, Bianca M.
AU - Amusat, Oluwamayowa O.
AU - Park, Jangho
AU - Bartholomew, Timothy V.
AU - Gunter, Dan
AU - Achilli, Andrea
N1 - Publisher Copyright: © 2023 Elsevier Ltd
PY - 2023/7
Y1 - 2023/7
N2 - Ultrafiltration (UF) has been widely utilized as water pretreatment for different applications especially in water reuse. The UF system operation is characterized by a filtration phase, where particles accumulate on the membrane surface resulting in an increase in the transmembrane pressure (TMP) and a cleaning phase, where foulants are removed through cleaning cycles including physical backwash and chemical-enhanced backwash (CEB). In this study, data from an engineering-scale UF system treating reclaimed wastewater were used to assess the impact of backwashing on the filtration process. TMP backwash trigger, backwash duration, and CEB frequency were purposely varied for a cycle-by-cycle investigation on the net water production, water recovery, initial operating TMP, and filtration cycle duration. As the TMP backwash trigger was varied between 62 and 145 kPa, the maximum net water production (63 m3/d) was achieved at 103 kPa and water recovery remained relatively constant at approximately 92 %. Backwash durations of 45, 65, and 85 s were performed where both net water production and water recovery yielded similar results (~63 m3/d and ~ 91 %) compared with 103 kPa TMP backwash trigger. The CEB frequency was also lowered from one every three backwashes (1/3) to 1/6 and 1/12 and resulted in decreased net water production and water recovery while the initial TMP increased. Interestingly, the total number of CEBs remained approximately constant regardless of their frequency. Results suggest that CEB is an important fouling control process to maximize water production.
AB - Ultrafiltration (UF) has been widely utilized as water pretreatment for different applications especially in water reuse. The UF system operation is characterized by a filtration phase, where particles accumulate on the membrane surface resulting in an increase in the transmembrane pressure (TMP) and a cleaning phase, where foulants are removed through cleaning cycles including physical backwash and chemical-enhanced backwash (CEB). In this study, data from an engineering-scale UF system treating reclaimed wastewater were used to assess the impact of backwashing on the filtration process. TMP backwash trigger, backwash duration, and CEB frequency were purposely varied for a cycle-by-cycle investigation on the net water production, water recovery, initial operating TMP, and filtration cycle duration. As the TMP backwash trigger was varied between 62 and 145 kPa, the maximum net water production (63 m3/d) was achieved at 103 kPa and water recovery remained relatively constant at approximately 92 %. Backwash durations of 45, 65, and 85 s were performed where both net water production and water recovery yielded similar results (~63 m3/d and ~ 91 %) compared with 103 kPa TMP backwash trigger. The CEB frequency was also lowered from one every three backwashes (1/3) to 1/6 and 1/12 and resulted in decreased net water production and water recovery while the initial TMP increased. Interestingly, the total number of CEBs remained approximately constant regardless of their frequency. Results suggest that CEB is an important fouling control process to maximize water production.
KW - Backwash
KW - Data mining
KW - Membrane fouling
KW - Ultrafiltration
KW - Water reuse
UR - http://www.scopus.com/inward/record.url?scp=85160431757&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85160431757&partnerID=8YFLogxK
U2 - 10.1016/j.jwpe.2023.103761
DO - 10.1016/j.jwpe.2023.103761
M3 - Article
SN - 2214-7144
VL - 53
JO - Journal of Water Process Engineering
JF - Journal of Water Process Engineering
M1 - 103761
ER -