TY - JOUR
T1 - Between-day repeatability of sensor-based in-home gait assessment among older adults
T2 - assessing the effect of frailty
AU - Pradeep Kumar, Danya
AU - Wendel, Christopher
AU - Mohler, Jane
AU - Laksari, Kaveh
AU - Toosizadeh, Nima
N1 - Publisher Copyright: © 2020, Springer Nature Switzerland AG.
PY - 2021/6
Y1 - 2021/6
N2 - Background: While sensor-based daily physical activity (DPA) gait assessment has been demonstrated to be an effective measure of physical frailty and fall-risk, the repeatability of DPA gait parameters between different days of measurement is not clear. Aims: To evaluate test–retest reliability (repeatability) of DPA gait performance parameters, representing the quality of walking, and quantitative gait measures (e.g. number of steps) between two separate days of assessment among older adults. Methods: DPA was acquired for 48-h from older adults (age ≥ 65 years) using a tri-axial accelerometer. Continuous walking bouts (≥ 60 s) were identified from acceleration data and used to extract gait performance parameters, including time- and frequency-domain gait parameters, representing walking speed, variability, and irregularity. To assess repeatability, intraclass correlation coefficient (ICC) was calculated using two-way mixed effects F-test models for day-1 vs. day-2 as the independent random effect. Repeatability tests were performed for all participants and also within frailty groups (non-frail and pre-frail/frail identified using Fried phenotype). Results: Data was analyzed from 63 older adults (29 non-frail and 34 pre-frail/frail). Most of the time- and frequency-domain gait performance parameters showed good to excellent repeatability (ICC ≥ 0.70), while quantitative parameters, including number of steps and walking duration showed poor repeatability (ICC < 0.30). Among majority of the gait performance parameters, we observed higher repeatability among the pre-frail/frail group (ICC > 0.78) compared to non-frail individuals (0.39 < ICC < 0.55). Conclusion: Gait performance parameters, showed higher repeatability compared to quantitative measures. Higher repeatability among pre-frail/frail individuals may be attributed to a reduced functional capacity for performing more intense and variable physical tasks. Trial registration: The clinical trial was retrospectively registered on June 18th, 2013 with ClinicalTrials.gov, identifier NCT01880229.
AB - Background: While sensor-based daily physical activity (DPA) gait assessment has been demonstrated to be an effective measure of physical frailty and fall-risk, the repeatability of DPA gait parameters between different days of measurement is not clear. Aims: To evaluate test–retest reliability (repeatability) of DPA gait performance parameters, representing the quality of walking, and quantitative gait measures (e.g. number of steps) between two separate days of assessment among older adults. Methods: DPA was acquired for 48-h from older adults (age ≥ 65 years) using a tri-axial accelerometer. Continuous walking bouts (≥ 60 s) were identified from acceleration data and used to extract gait performance parameters, including time- and frequency-domain gait parameters, representing walking speed, variability, and irregularity. To assess repeatability, intraclass correlation coefficient (ICC) was calculated using two-way mixed effects F-test models for day-1 vs. day-2 as the independent random effect. Repeatability tests were performed for all participants and also within frailty groups (non-frail and pre-frail/frail identified using Fried phenotype). Results: Data was analyzed from 63 older adults (29 non-frail and 34 pre-frail/frail). Most of the time- and frequency-domain gait performance parameters showed good to excellent repeatability (ICC ≥ 0.70), while quantitative parameters, including number of steps and walking duration showed poor repeatability (ICC < 0.30). Among majority of the gait performance parameters, we observed higher repeatability among the pre-frail/frail group (ICC > 0.78) compared to non-frail individuals (0.39 < ICC < 0.55). Conclusion: Gait performance parameters, showed higher repeatability compared to quantitative measures. Higher repeatability among pre-frail/frail individuals may be attributed to a reduced functional capacity for performing more intense and variable physical tasks. Trial registration: The clinical trial was retrospectively registered on June 18th, 2013 with ClinicalTrials.gov, identifier NCT01880229.
KW - Continuous walking
KW - Daily physical activity
KW - Frailty
KW - Gait performance parameters
KW - Repeatability
UR - http://www.scopus.com/inward/record.url?scp=85091064218&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85091064218&partnerID=8YFLogxK
U2 - 10.1007/s40520-020-01686-x
DO - 10.1007/s40520-020-01686-x
M3 - Article
C2 - 32930988
SN - 1594-0667
VL - 33
SP - 1529
EP - 1537
JO - Aging Clinical and Experimental Research
JF - Aging Clinical and Experimental Research
IS - 6
ER -