T1 - Critical Comparison between Large and Mini Vertical Flow Immunoassay Platforms forYersinia PestisDetection
AU - Devadhasan, Jasmine Pramila
AU - Gu, Jian
AU - Chen, Peng
AU - Smith, Stanley
AU - Thomas, Baiju
AU - Gates-Hollingsworth, Marcellene
AU - Hau, Derrick
AU - Pandit, Sujata
AU - AuCoin, David
AU - Zenhausern, Frederic
N1 - Funding Information: This work was supported by the Chemical Biological Technologies Directorate (Contract # HDTRA1-16-C-0026) and the Advanced Technology International (Contract # MCDC-18-04-09-002) from the Department of Defense Chemical and Biological Defense program through the Defense Threat Reduction Agency (DTRA). Publisher Copyright: © 2021 American Chemical Society
PY - 2021/7/13
Y1 - 2021/7/13
N2 - Yersinia pestisis a Gram-negative bacterium that is the causative agent of plague and is widely recognized as a potential biological weapon. Due to the high fatality rate of plague when diagnosis is delayed, the development of rapid, sensitive, specific, and cost-effective methods is needed for its diagnosis. TheY. pestislow calcium response V (LcrV) protein has been identified as a potential microbial biomarker for the diagnosis of plague. In this paper, we present a highly sensitive, paper-based, vertical flow immunoassay (VFI) prototype for the detection of LcrV and the diagnosis of plague. An antigen-capture assay using monoclonal antibodies is employed to capture and detect the LcrV protein, using a colorimetric approach. In addition, the effect of miniaturizing the VFI device is explored based on two different sizes of VFI platforms, denoted as “large VFI” and “mini VFI.” Also, a comparative analysis is performed between the VFI platform and a lateral flow immunoassay (LFI) platform to exhibit the improved assay sensitivity suitable for point-of-care (POC) diagnostics. The analytical sensitivity or limit of detection (LOD) in the mini VFI is approximately 0.025 ng/mL, that is, 10 times better than that of the large VFI platform or 80 times over a standard lateral flow configuration. The low LOD of the LcrV VFI appears to be highly suitable for testing clinical samples and potentially diagnosing plague at earlier time points. In addition, optimization of the gold nanoparticle (AuNP) concentration, nanomaterial plasmonic properties, and flow velocity analysis could improve the performance of the VFI. Furthermore, we developed automated image analysis software that shows potential for integrating the diagnostic system into a smartphone. These methods and findings demonstrate that the VFI platform is a highly sensitive device for detecting the LcrV and potentially many other biomarkers.
AB - Yersinia pestisis a Gram-negative bacterium that is the causative agent of plague and is widely recognized as a potential biological weapon. Due to the high fatality rate of plague when diagnosis is delayed, the development of rapid, sensitive, specific, and cost-effective methods is needed for its diagnosis. TheY. pestislow calcium response V (LcrV) protein has been identified as a potential microbial biomarker for the diagnosis of plague. In this paper, we present a highly sensitive, paper-based, vertical flow immunoassay (VFI) prototype for the detection of LcrV and the diagnosis of plague. An antigen-capture assay using monoclonal antibodies is employed to capture and detect the LcrV protein, using a colorimetric approach. In addition, the effect of miniaturizing the VFI device is explored based on two different sizes of VFI platforms, denoted as “large VFI” and “mini VFI.” Also, a comparative analysis is performed between the VFI platform and a lateral flow immunoassay (LFI) platform to exhibit the improved assay sensitivity suitable for point-of-care (POC) diagnostics. The analytical sensitivity or limit of detection (LOD) in the mini VFI is approximately 0.025 ng/mL, that is, 10 times better than that of the large VFI platform or 80 times over a standard lateral flow configuration. The low LOD of the LcrV VFI appears to be highly suitable for testing clinical samples and potentially diagnosing plague at earlier time points. In addition, optimization of the gold nanoparticle (AuNP) concentration, nanomaterial plasmonic properties, and flow velocity analysis could improve the performance of the VFI. Furthermore, we developed automated image analysis software that shows potential for integrating the diagnostic system into a smartphone. These methods and findings demonstrate that the VFI platform is a highly sensitive device for detecting the LcrV and potentially many other biomarkers.
UR - http://www.scopus.com/inward/record.url?scp=85106357887&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85106357887&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.0c05278
DO - 10.1021/acs.analchem.0c05278
M3 - Article
SN - 0003-2700
VL - 93
SP - 9337
EP - 9344
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 27
ER -