N2 - This paper reports a design modification of a biochip microchannel plasma blood separator. Among the three geometric characteristics, i.e. bifurcation, constriction and bending channel, which have been widely used in promoting biofluid separation, the original separator (Figure 1) has put the focus on the bifurcation effect and also adopts a constriction at the inlet end to implement some constriction effect. This modification is targeted to a strong integrative application of these three channel geometries characteristics. For this purpose, curve/arc constrictions are implemented inside the bifurcation region between bifurcations, so that both constriction and bending channel effects can be effectively fulfilled at each bifurcation to increase the effectiveness. Both 2D and 3D designs for fulfilling this modification are offered. The flow field and separation process in the modified 2D biochip are analyzed using computational fluid dynamics (CFD) technique and compared with the original separator. Comparably the modified design leads to more volumetric separation of plasma rich fluid from the side channels and results in low flow rate ratio due to the increased channel resistance in the main channel. Improvements in using constriction and bending channel effects have been numerically evidenced.
AB - This paper reports a design modification of a biochip microchannel plasma blood separator. Among the three geometric characteristics, i.e. bifurcation, constriction and bending channel, which have been widely used in promoting biofluid separation, the original separator (Figure 1) has put the focus on the bifurcation effect and also adopts a constriction at the inlet end to implement some constriction effect. This modification is targeted to a strong integrative application of these three channel geometries characteristics. For this purpose, curve/arc constrictions are implemented inside the bifurcation region between bifurcations, so that both constriction and bending channel effects can be effectively fulfilled at each bifurcation to increase the effectiveness. Both 2D and 3D designs for fulfilling this modification are offered. The flow field and separation process in the modified 2D biochip are analyzed using computational fluid dynamics (CFD) technique and compared with the original separator. Comparably the modified design leads to more volumetric separation of plasma rich fluid from the side channels and results in low flow rate ratio due to the increased channel resistance in the main channel. Improvements in using constriction and bending channel effects have been numerically evidenced.
UR - https://www.scopus.com/pages/publications/78449300978
UR - https://www.scopus.com/pages/publications/78449300978#tab=citedBy
U2 - 10.1109/ICEPT.2010.5582861
DO - 10.1109/ICEPT.2010.5582861
M3 - Conference contribution
SN - 9781424481422
T3 - Proceedings - 2010 11th International Conference on Electronic Packaging Technology and High Density Packaging, ICEPT-HDP 2010
SP - 691
EP - 697
BT - Proceedings - 2010 11th International Conference on Electronic Packaging Technology and High Density Packaging, ICEPT-HDP 2010
T2 - 2010 11th International Conference on Electronic Packaging Technology and High Density Packaging, ICEPT-HDP 2010
Y2 - 16 August 2010 through 19 August 2010
ER -