TY - GEN
T1 - Design of a robotic system for MRI-guided deep brain stimulation electrode placement
AU - Cole, Gregory
AU - Pilitsis, Julie
AU - Fischer, Gregory S.
PY - 2009
Y1 - 2009
N2 - Deep brain stimulation (DBS) is a technique for influencing brain function though the use of implanted electrodes. Direct magnetic resonance (MR) image guidance during DBS insertion would provide many benefits; most significantly, interventional MRI can be used for planning, monitoring of tissue deformation, real-time visualization of insertion, and confirmation of placement. The accuracy of standard stereotactic insertion is limited by registration errors and brain movement during surgery. With real-time acquisition of highresolution MR images during insertion, probe placement can be confirmed intra-operatively. Direct MR guidance has not yet taken hold because it is often confounded by a number of issues including: MR-compatibility of existing stereotactic surgery equipment and patient access in the scanner bore. The high resolution images required for neurosurgical planning and guidance require high-field MR (1.5-3T); thus, any system must be capable of working within the constraints of a closed, longbore diagnostic magnet. Currently, no technological solution exists to assist MRI guided neurosurgical interventions in an accurate, simple, and economical manner.We present the design of a robotic assistant system that overcomes these difficulties and promises safe and reliable electrode placement in the brain inside closed high-field MRI scanners. The robot performs the insertion under real-time 3T MR image guidance. This paper described analysis of the workspace requirements, MR compatibility evaluation, and mechanism design.
AB - Deep brain stimulation (DBS) is a technique for influencing brain function though the use of implanted electrodes. Direct magnetic resonance (MR) image guidance during DBS insertion would provide many benefits; most significantly, interventional MRI can be used for planning, monitoring of tissue deformation, real-time visualization of insertion, and confirmation of placement. The accuracy of standard stereotactic insertion is limited by registration errors and brain movement during surgery. With real-time acquisition of highresolution MR images during insertion, probe placement can be confirmed intra-operatively. Direct MR guidance has not yet taken hold because it is often confounded by a number of issues including: MR-compatibility of existing stereotactic surgery equipment and patient access in the scanner bore. The high resolution images required for neurosurgical planning and guidance require high-field MR (1.5-3T); thus, any system must be capable of working within the constraints of a closed, longbore diagnostic magnet. Currently, no technological solution exists to assist MRI guided neurosurgical interventions in an accurate, simple, and economical manner.We present the design of a robotic assistant system that overcomes these difficulties and promises safe and reliable electrode placement in the brain inside closed high-field MRI scanners. The robot performs the insertion under real-time 3T MR image guidance. This paper described analysis of the workspace requirements, MR compatibility evaluation, and mechanism design.
UR - https://www.scopus.com/pages/publications/70350379592
UR - https://www.scopus.com/pages/publications/70350379592#tab=citedBy
U2 - 10.1109/ROBOT.2009.5152343
DO - 10.1109/ROBOT.2009.5152343
M3 - Conference contribution
SN - 9781424427895
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 4450
EP - 4456
BT - 2009 IEEE International Conference on Robotics and Automation, ICRA '09
T2 - 2009 IEEE International Conference on Robotics and Automation, ICRA '09
Y2 - 12 May 2009 through 17 May 2009
ER -