N2 - Background: The Octopus endovascular strategy involves placement of multiple, stacked bifurcated grafts in the thoracic segment of a thoracoabdominal aneurysm (TAAA) to facilitate deployment of multiple parallel covered stents for visceral perfusion. This study aimed to review early outcomes of the Octopus TAAA repair strategy at a tertiary, high-volume referral center. Methods: All patients who underwent this Octopus procedure from 2015 to 2018 were reviewed from a prospectively collected single-institution registry. Demographics, comorbidities, and aneurysm anatomy including side and extent, perioperative data including blood loss, length of procedure length of stay, morbidity, and mortality up to 3 years after the procedure were elevated. Results: A total of 21 patients (48% female, age 72.9 years) underwent the Octopus procedure over the study period. Mean TAAA diameter was 6.7 cm, with 14% dissection related and 86% degenerative TAAA. All patients had been turned down for open repair and 3 (14%) were performed urgently of which 2 were ruptures. TAAA extent was 9% type 2, 62% type 3, and 29% type 4. A mean of 3.04 branches were revascularized per patient, with the superior mesenteric artery (SMA) (90%) perfused through its own limb, and both renals usually reconstructed in parallel graft fashion (left 90%, right 85.7%) with the distal abdominal extension through one of the limbs. Mean operative time was 8 hr, fluoroscopy time 164 min, contrast 182 mL, and blood loss 807 mL. We staged the thoracic and juxtavisceral portions of the cases in 24% of patients. 90% of cases were able to be completed with exclusion of the TAAA and all planned visceral branches cannulated. Perioperative complications included paraplegia (19%) (13.3% permanent, 26.6% temporary), acute kidney injury (24%), prolonged ventilation (19%), myocardial infarction (4.9%), and ischemic bowel (4.8%). Median follow-up was 13.5 months (range 1–26 months). At latest follow-up, type I endoleak rate was 9.5%, with all being treated with proximal cuffs. Other second interventions included restenting of a right renal, angioplasty of an iliac limb kink, and type 2 endoleak coiling. Primary patency of visceral branches was 93.8% at latest follow-up (celiac 100%, SMA 94.7%, right renal 88.9%, left renal 94.8%). In-hospital all-cause mortality rate was 14.2%, with 30-day survival being 90.5%, 6-month survival was 88.3%, one-year survival 71.4%, and 3-year survival was 52.1%. Conclusions: The Octopus procedure is a high-risk option for urgent or emergent endovascular TAAA repair with off-the-shelf devices in patients who are not candidates for open repair.
AB - Background: The Octopus endovascular strategy involves placement of multiple, stacked bifurcated grafts in the thoracic segment of a thoracoabdominal aneurysm (TAAA) to facilitate deployment of multiple parallel covered stents for visceral perfusion. This study aimed to review early outcomes of the Octopus TAAA repair strategy at a tertiary, high-volume referral center. Methods: All patients who underwent this Octopus procedure from 2015 to 2018 were reviewed from a prospectively collected single-institution registry. Demographics, comorbidities, and aneurysm anatomy including side and extent, perioperative data including blood loss, length of procedure length of stay, morbidity, and mortality up to 3 years after the procedure were elevated. Results: A total of 21 patients (48% female, age 72.9 years) underwent the Octopus procedure over the study period. Mean TAAA diameter was 6.7 cm, with 14% dissection related and 86% degenerative TAAA. All patients had been turned down for open repair and 3 (14%) were performed urgently of which 2 were ruptures. TAAA extent was 9% type 2, 62% type 3, and 29% type 4. A mean of 3.04 branches were revascularized per patient, with the superior mesenteric artery (SMA) (90%) perfused through its own limb, and both renals usually reconstructed in parallel graft fashion (left 90%, right 85.7%) with the distal abdominal extension through one of the limbs. Mean operative time was 8 hr, fluoroscopy time 164 min, contrast 182 mL, and blood loss 807 mL. We staged the thoracic and juxtavisceral portions of the cases in 24% of patients. 90% of cases were able to be completed with exclusion of the TAAA and all planned visceral branches cannulated. Perioperative complications included paraplegia (19%) (13.3% permanent, 26.6% temporary), acute kidney injury (24%), prolonged ventilation (19%), myocardial infarction (4.9%), and ischemic bowel (4.8%). Median follow-up was 13.5 months (range 1–26 months). At latest follow-up, type I endoleak rate was 9.5%, with all being treated with proximal cuffs. Other second interventions included restenting of a right renal, angioplasty of an iliac limb kink, and type 2 endoleak coiling. Primary patency of visceral branches was 93.8% at latest follow-up (celiac 100%, SMA 94.7%, right renal 88.9%, left renal 94.8%). In-hospital all-cause mortality rate was 14.2%, with 30-day survival being 90.5%, 6-month survival was 88.3%, one-year survival 71.4%, and 3-year survival was 52.1%. Conclusions: The Octopus procedure is a high-risk option for urgent or emergent endovascular TAAA repair with off-the-shelf devices in patients who are not candidates for open repair.
UR - http://www.scopus.com/inward/record.url?scp=85072371414&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072371414&partnerID=8YFLogxK
U2 - 10.1016/j.avsg.2019.05.043
DO - 10.1016/j.avsg.2019.05.043
M3 - Article
C2 - 31394231
SN - 0890-5096
VL - 61
SP - 350
EP - 355