Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis

Gopal R. Vijayaraghavan, Srinivasan Vedantham, Vikram Rangan, Adib Karam, Larry Zheng, Abhijit Roychowdhury, Sarwat Hussain

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Purpose: To analyze the effect of lobe selection, needle gauge, and number of passes on procedure outcomes in terms of specimen length and post-procedure complications. Methods: In this HIPAA-compliant, IRB-approved retrospective study, the data from 771 ultrasound-guided adult parenchymal liver biopsies were analyzed. Post-procedure complications were assigned a 3-point rating scale. Associations between specimen length and post-procedure complications with lobe laterality, needle gauge, and number of passes were analyzed. Multivariate logistic regression models were used to analyze the likelihood for achieving a specimen length of at least 2 cm. Results: Post-procedure complications were not associated with lobe laterality, needle gauge, and number of passes (p > 0.3). Specimen length was associated with the number of passes dichotomized at the study mean (p = 0.007), but not with lobe laterality or needle gauge (p > 0.2). After adjusting for lobe laterality and needle gauge, procedures with 1 or 2 passes were associated with a higher likelihood of obtaining a 2 cm or longer specimen (OR 2.469; CI 1.08–5.63, p = 0.0315) than procedures with 3 or more passes, possibly due to poorer sample quality. After adjusting for lobe laterality, an 18-gauge needle was associated with higher odds of a biopsy procedure with 1 or 2 passes (OR 3.665; CI 1.93–6.95, p < 0.0001) than a 20-gauge needle. Conclusions: Lobe laterality was not associated with specimen length or post-procedure complications. An 18-gauge needle compared to a 20-gauge needle could reduce the need for a procedure with more than 2 passes. There was no difference in post-procedure complications between the two needle sizes.

Original languageEnglish (US)
Pages (from-to)1223-1229
Number of pages7
JournalAbdominal Imaging
Volume40
Issue number5
DOIs
StatePublished - Jun 1 2015
Externally publishedYes

Keywords

  • Hepatitis (C06.552.380)
  • Image-guided biopsy (E01.370.388.100.370)
  • Liver (A03.620)
  • Ultrasonography (E01.370.350.850)

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging
  • Gastroenterology
  • Urology

Fingerprint

Dive into the research topics of 'Effect of needle gauge and lobe laterality on parenchymal liver biopsy outcome: a retrospective analysis'. Together they form a unique fingerprint.

Cite this