TY - GEN
T1 - Efficiency optimization of dual active bridge converter based on dv/dt snubber capacitors
AU - Xu, Wei
AU - Vetrivelan, Adithyan
AU - Guo, Zhicheng
AU - Yu, Ruiyang
AU - Huang, Alex Q.
N1 - Publisher Copyright: © 2021 IEEE.
PY - 2021/6/14
Y1 - 2021/6/14
N2 - This paper presents a lossless regenerative dV/dt snubber circuit for PWM converters to achieve high-efficiency high power-density without significant cost and reliability penalties. The dV/dt snubber employs lossless capacitors for each MOSFET device in a converter to provide an additional path to store the switching energy during turn-off transient and decrease the actual turn-off loss of the MOSFET channel. A novel mathematical turn-off loss model is built to separate the actual turn-off loss of the MOSFET channel and the recycling switching energy stored in the total equivalent output capacitance including Coss, the dV/dt snubber, and etc. Necessary snubber optimization strategy is proposed in order to balance the turn-off loss with ZVS operation range and deadtime conduction loss, and thereby achieving an optimal efficiency performance. To prove the validity and accuracy of the novel turn-off loss model and optimization strategy, the dV/dt snubber has been incorporated into a 1.3kV/200kW DC/DC and a 1kV/70kVA DC/AC PWM converters. Experimental results are given to demonstrate the validity of the proposed dV/dt snubber capacitors and optimization strategy.
AB - This paper presents a lossless regenerative dV/dt snubber circuit for PWM converters to achieve high-efficiency high power-density without significant cost and reliability penalties. The dV/dt snubber employs lossless capacitors for each MOSFET device in a converter to provide an additional path to store the switching energy during turn-off transient and decrease the actual turn-off loss of the MOSFET channel. A novel mathematical turn-off loss model is built to separate the actual turn-off loss of the MOSFET channel and the recycling switching energy stored in the total equivalent output capacitance including Coss, the dV/dt snubber, and etc. Necessary snubber optimization strategy is proposed in order to balance the turn-off loss with ZVS operation range and deadtime conduction loss, and thereby achieving an optimal efficiency performance. To prove the validity and accuracy of the novel turn-off loss model and optimization strategy, the dV/dt snubber has been incorporated into a 1.3kV/200kW DC/DC and a 1kV/70kVA DC/AC PWM converters. Experimental results are given to demonstrate the validity of the proposed dV/dt snubber capacitors and optimization strategy.
KW - DAB
KW - Optimization
KW - Snubber capacitors
UR - https://www.scopus.com/pages/publications/85115720838
UR - https://www.scopus.com/pages/publications/85115720838#tab=citedBy
U2 - 10.1109/APEC42165.2021.9487159
DO - 10.1109/APEC42165.2021.9487159
M3 - Conference contribution
T3 - Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
SP - 647
EP - 653
BT - 2021 IEEE Applied Power Electronics Conference and Exposition, APEC 2021
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 36th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2021
Y2 - 14 June 2021 through 17 June 2021
ER -