T1 - Field Study of Nighttime Leakage Currents in Bifacial PV Modules
T2 - 52nd IEEE Photovoltaic Specialist Conference, PVSC 2024
AU - Molto, Cecile
AU - Smith, Ryan
AU - Colvin, Dylan J.
AU - Hacke, Peter
AU - Dirubio, Christopher
AU - Gardeski, Matthew
AU - Li, Fang
AU - Oh, Jaewon
AU - Tamizhmani, Govindasamy
AU - Raupp, Christopher
AU - Mallieni, Jaya
AU - Shrestha, Sanjay
AU - Broker, Paul
AU - Seigneur, Hubert
N1 - Publisher Copyright: © 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150-200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.
AB - Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150-200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.
UR - https://www.scopus.com/pages/publications/85211579549
UR - https://www.scopus.com/pages/publications/85211579549#tab=citedBy
U2 - 10.1109/PVSC57443.2024.10749087
DO - 10.1109/PVSC57443.2024.10749087
M3 - Conference contribution
T3 - Conference Record of the IEEE Photovoltaic Specialists Conference
SP - 368
EP - 372
BT - 2024 IEEE 52nd Photovoltaic Specialist Conference, PVSC 2024
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 9 June 2024 through 14 June 2024
ER -