TY - JOUR
T1 - Impact of dynamical scattering on quantitative contrast for aberration-corrected transmission electron microscope images
AU - Wen, C.
AU - Smith, David
N1 - Funding Information: The work was supported by the National Natural Science Foundation of China (Grant No. 11104226 ), and the State Scholarship Fund of China from China Scholarship Council (File No. 201508510033 ). One author (C. Wen) thanks Allison Boley for comments on the manuscript. Publisher Copyright: © 2016 Elsevier Ltd
PY - 2016/10/1
Y1 - 2016/10/1
N2 - Aberration-corrected transmission electron microscope images taken under optimum-defocus conditions or processed offline can correctly reflect the projected crystal structure with atomic resolution. However, dynamical scattering, which will seriously influence image contrast, is still unavoidable. Here, the multislice image simulation approach was used to quantify the impact of dynamical scattering on the contrast of aberration-corrected images for a 3C-SiC specimen with changes in atomic occupancy and thickness. Optimum-defocus images with different spherical aberration (CS) coefficients, and structure images restored by deconvolution processing, were studied. The results show that atomic-column positions and the atomic occupancy for SiC ‘dumbbells’ can be determined by analysis of image contrast profiles only below a certain thickness limit. This limit is larger for optimum-defocus and restored structure images with negative CS coefficient than those with positive CS coefficient. The image contrast of C (or Si) atomic columns with specific atomic occupancy changes differently with increasing crystal thickness. Furthermore, contrast peaks for C atomic columns overlapping with neighboring peaks of Si atomic columns with varied Si atomic occupancy, which is enhanced with increasing crystal thickness, can be neglected in restored structure images, but the effect is substantial in optimum-defocus images.
AB - Aberration-corrected transmission electron microscope images taken under optimum-defocus conditions or processed offline can correctly reflect the projected crystal structure with atomic resolution. However, dynamical scattering, which will seriously influence image contrast, is still unavoidable. Here, the multislice image simulation approach was used to quantify the impact of dynamical scattering on the contrast of aberration-corrected images for a 3C-SiC specimen with changes in atomic occupancy and thickness. Optimum-defocus images with different spherical aberration (CS) coefficients, and structure images restored by deconvolution processing, were studied. The results show that atomic-column positions and the atomic occupancy for SiC ‘dumbbells’ can be determined by analysis of image contrast profiles only below a certain thickness limit. This limit is larger for optimum-defocus and restored structure images with negative CS coefficient than those with positive CS coefficient. The image contrast of C (or Si) atomic columns with specific atomic occupancy changes differently with increasing crystal thickness. Furthermore, contrast peaks for C atomic columns overlapping with neighboring peaks of Si atomic columns with varied Si atomic occupancy, which is enhanced with increasing crystal thickness, can be neglected in restored structure images, but the effect is substantial in optimum-defocus images.
KW - 3C-SiC
KW - Aberration-corrected transmission electron microscopy
KW - Atomic occupancy
KW - Atomic-column position
KW - Dynamical scattering
KW - Image contrast
UR - http://www.scopus.com/inward/record.url?scp=84981357112&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84981357112&partnerID=8YFLogxK
U2 - 10.1016/j.micron.2016.07.008
DO - 10.1016/j.micron.2016.07.008
M3 - Article
SN - 0968-4328
VL - 89
SP - 77
EP - 86
JO - Micron
JF - Micron
ER -