In-Stent Restenosis Limitation with Stent-based Controlled-Release Nitric Oxide: Initial Results in Rabbits

Young S. Do, Edward Y. Kao, Fumikiyo Ganaha, Hiroki Minamiguchi, Koji Sugimoto, Jane Lee, Christopher J. Elkins, Philippe G. Amabile, Michael D. Kuo, David S. Wang, Jacob M. Waugh, Michael D. Dake

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

PURPOSE: To evaluate effect of controlled stent-based release of an NO donor to limit in-stent restenosis in rabbits. MATERIALS AND METHODS: Bioerodable microspheres containing NO donor or biodegradable polymer (polylactide-co-glycolide-polyethylene glycol) were prepared and loaded in channeled stents. Daily concentrations of NO release from NO-containing microspheres were assayed in vitro. NO- and polymer-containing (control) microsphere-loaded stents were deployed in aortas of New Zealand white rabbits (n = 8). Aortas with stents were harvested at 7 (n = 5) and 28 days (n = 3) and evaluated for cyclic guanosine monophosphate (cGMP) levels (7 days), number of proliferating cell nuclear antigen-positive cells (7 days), and intima-to-media ratio (7 and 28 days), with statistical significance evaluated by using one-way analysis of variance. RESULTS: NO-containing microspheres released NO with an initial bolus in the 1st week, followed by sustained release for the remaining 3 weeks. Significant increase in cGMP levels and decrease in proliferating cell nuclear antigen-positive cells were found at 7 days for the NO-treated group relative to controls (P < .05). Intima-to-media ratio in the NO-treated group was reduced by 46% and 32% relative to controls at 7 and 28 days, respectively (mean, 0.14 ± 0.01 [standard error] vs 0.26 ± 0.02 at 7 days, P < .01; 1.34 ± 0.05 vs 1.98 ± 0.08 at 28 days, P < .01). CONCLUSION: Stent-based controlled release of NO donor significantly reduces in-stent restenosis and is associated with increase in vascular cGMP and suppression of proliferation.

Original languageEnglish (US)
Pages (from-to)377-382
Number of pages6
JournalRadiology
Volume230
Issue number2
DOIs
StatePublished - Feb 2004

Keywords

  • Animals Arteries
  • Arteries
  • Experimental study Stents and prostheses
  • Femoral
  • Restenosis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'In-Stent Restenosis Limitation with Stent-based Controlled-Release Nitric Oxide: Initial Results in Rabbits'. Together they form a unique fingerprint.

Cite this