Abstract
Biological products and specimens often require consistent ultracold storage to preserve their integrity. Existing time-temperature indicators (TTIs) are inadequate for monitoring ultracold conditions at the individual aliquot level. We adapted the autocatalytic permanganate-oxalate reaction to create visual TTIs functional below 0 °C. Using eutectic compositions of LiClO4, NaClO4, and Mg(ClO4)2, we depressed the melting points of the reaction mixtures to −18 °C, −37 °C, and −67 °C, respectively. The incorporation of perchlorate salts as antifreeze systems did not derail the kinetic behavior of the permanganate-oxalate reaction and allowed the reactions to pause below their melting points. Here, we developed and characterized eight customized TTIs, running from five minutes at 25 °C to 7 days at −20 °C. Temperature sensitivity was consistent with Arrhenius behavior (i.e., exponential increases in run time with linear decreases in temperature). The TTIs exhibited good accuracy and reproducibility, with within-batch and between-batch run-time precision at the targeted temperatures of ≤4.8% CV and ≤7.5% CV, respectively. The average absorbance vs. time trajectories, expressed as RMSD %CVs, were 4.5% for intra-batch and 10.4% for inter-batch runs. Indicators withstood multiple freeze/thaw cycles or extended pre-freezing periods with minimal impact on reaction kinetics. Once activated and stored below their melting points, TTIs maintained color intensity for at least 12 months. This work establishes the permanganate-oxalate system in eutectic perchlorate-based antifreeze solutions as a simple, inexpensive approach for ultracold-active TTIs, offering customizable kinetics and robust performance. The described TTIs can serve to improve quality monitoring of biologicals and biospecimens during ultracold storage and handling.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 1741-1757 |
| Number of pages | 17 |
| Journal | Reaction Chemistry and Engineering |
| Volume | 10 |
| Issue number | 8 |
| DOIs | |
| State | Published - Jul 23 2025 |
ASJC Scopus subject areas
- Catalysis
- Chemistry (miscellaneous)
- Chemical Engineering (miscellaneous)
- Process Chemistry and Technology
- Fluid Flow and Transfer Processes
Fingerprint
Dive into the research topics of 'Kinetically tunable, subzero-active, visual time-temperature indicators based on the permanganate-oxalate reaction'. Together they form a unique fingerprint.Press/Media
-
Investigators at Arizona State University Report Findings in Reaction Chemistry and Engineering (Kinetically Tunable, Subzero-active, Visual Time-temperature Indicators Based On the Permanganate-oxalate Reaction)
7/9/25
1 item of Media coverage
Press/Media: Press / Media
Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS