T1 - Lab-on-a-chip immunoassay for multiple antibodies using microsphere light scattering and quantum dot emission
AU - Lucas, Lonnie J.
AU - Chesler, Jennine
AU - Yoon, Jeong Yeol
N1 - Funding Information: The authors are grateful to Mr. Jin-Hee Han at the University of Arizona (UA) for the fabrication of microfluidic devices and Micro/Nanofabrication Center (MFC) at UA for the cleanroom facility and subsequent equipment assistance. The funding for this research was provided by National Veterinary Research and Quarantine Service (NVRQS), Republic of Korea, award no. C-AD14-2006-11-1, and the U.S. National Science Foundation (NSF), award no. EEC-0600855. JNC also acknowledges the support from UA/NASA Space Grant undergraduate internship.
PY - 2007
Y1 - 2007
N2 - Detection of multiple biomarkers has recently received great interest from the biosensors community. These diagnostic methods must be rapid, specific, sensitive, and cost-effective. In 2006, our group demonstrated a successful lab-on-a-chip immunoassay using microsphere light scattering, which is essentially a one-step, automated protocol, on a reusable chip. In the past, this had been difficult due to the limitations of microfluidic mixing and false-positive readings of particle immunoassays in a chip environment. In this current study, we conjugated quantum dots (QDs) onto microspheres to enable multiplex assays as well as to enhance the limit of detection (LOD). We named this configuration "nano-on-micro" or "NOM." Upon radiation with UVlight (380 nm), a stronger light scattering signal is observed with NOMs than QDs or microspheres alone. Additionally, NOMs are easier to handle than QDs. Since QDs also provide fluorescent emission, we are able to utilize an increase in light scattering for detecting antigen-antibody reaction and a decrease in QD emission to identify which antibody (or antigen) is present. Two types of NOM combinations were used. One batch of microspheres was coated with QDs emitting at 655 nm and mouse IgG (mlgG); the other with QDs emitting at 605 nm and bovine serum albumin (BSA). A mixture of these two NOMs was used to identify either anti-mlgG or anti-BSA. NOM particles and target solutions were mixed in a microfluidic device and on-chip detection was performed using proximity optical fibers. Forward light scattering at 380 nm was collected. With the positive target, the scattering signal was increased. The LOD was 25 ng ml-1 (165 pM) with p<0.05. Fluorescent emission (655 or 605 nm) was simultaneously collected. With the positive target, the emission signal was attenuated. Therefore, we were able to detect two different antibodies simultaneously with two different detection protocols. We believe this NOM bioassay has the ability to screen for and detect multiple antibodies with minimal sample processing and handling.
AB - Detection of multiple biomarkers has recently received great interest from the biosensors community. These diagnostic methods must be rapid, specific, sensitive, and cost-effective. In 2006, our group demonstrated a successful lab-on-a-chip immunoassay using microsphere light scattering, which is essentially a one-step, automated protocol, on a reusable chip. In the past, this had been difficult due to the limitations of microfluidic mixing and false-positive readings of particle immunoassays in a chip environment. In this current study, we conjugated quantum dots (QDs) onto microspheres to enable multiplex assays as well as to enhance the limit of detection (LOD). We named this configuration "nano-on-micro" or "NOM." Upon radiation with UVlight (380 nm), a stronger light scattering signal is observed with NOMs than QDs or microspheres alone. Additionally, NOMs are easier to handle than QDs. Since QDs also provide fluorescent emission, we are able to utilize an increase in light scattering for detecting antigen-antibody reaction and a decrease in QD emission to identify which antibody (or antigen) is present. Two types of NOM combinations were used. One batch of microspheres was coated with QDs emitting at 655 nm and mouse IgG (mlgG); the other with QDs emitting at 605 nm and bovine serum albumin (BSA). A mixture of these two NOMs was used to identify either anti-mlgG or anti-BSA. NOM particles and target solutions were mixed in a microfluidic device and on-chip detection was performed using proximity optical fibers. Forward light scattering at 380 nm was collected. With the positive target, the scattering signal was increased. The LOD was 25 ng ml-1 (165 pM) with p<0.05. Fluorescent emission (655 or 605 nm) was simultaneously collected. With the positive target, the emission signal was attenuated. Therefore, we were able to detect two different antibodies simultaneously with two different detection protocols. We believe this NOM bioassay has the ability to screen for and detect multiple antibodies with minimal sample processing and handling.
KW - Immunoagglutination
KW - Microfluidic device
KW - Multiplex assay
KW - On-chip detection
KW - Quantum dots
KW - Static light scattering
UR - http://www.scopus.com/inward/record.url?scp=35649006106&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=35649006106&partnerID=8YFLogxK
M3 - Paper
T2 - 2007 ASABE Annual International Meeting, Technical Papers
Y2 - 17 June 2007 through 20 June 2007
ER -