TY - JOUR
T1 - Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors
AU - Oxholm, Trevor M.
AU - Switzer, Eric R.
AU - Barrentine, Emily M.
AU - Essinger-Hileman, Thomas
AU - Hays-Wehle, James P.
AU - Mauskopf, Philip D.
AU - Noroozian, Omid
AU - Rahmani, Maryam
AU - Sinclair, Adrian K.
AU - Stephenson, Ryan
AU - Stevenson, Thomas R.
AU - Timbie, Peter T.
AU - Volpert, Carolyn
AU - Weeks, Eric
N1 - Funding Information: This work was supported by a 5-year NASA Astrophysics Research and Analysis (APRA 17-APRA17-0077) grant and NASA-Goddard Internal Research and Development funds, and TMO acknowledges support from the NASA-Goddard internship program and the UW-Madison graduate program. Publisher Copyright: © 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2022/12
Y1 - 2022/12
N2 - Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing high sensitivity measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420 to 540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.
AB - Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing high sensitivity measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420 to 540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.
KW - Far-infrared detector
KW - MKID
KW - Telescope
UR - http://www.scopus.com/inward/record.url?scp=85134825106&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134825106&partnerID=8YFLogxK
U2 - https://doi.org/10.1007/s10909-022-02760-6
DO - https://doi.org/10.1007/s10909-022-02760-6
M3 - Article
SN - 0022-2291
VL - 209
SP - 1038
EP - 1046
JO - Journal of Low Temperature Physics
JF - Journal of Low Temperature Physics
IS - 5-6
ER -