Abstract
A novel method of measuring the optical frequency stability of a continuous-wave (CW) laser by using an etalon-based optoelectronic oscillator is demonstrated. A 1000 finesse Fabry-Pérot etalon is used as a reference which eliminates the need of using an independent optical source as a frequency reference. Using this technique, the optical frequency stability of a CW laser is measured with ∼3.5-kHz optical frequency resolution at update rates of 90 Hz.
| Original language | English (US) |
|---|---|
| Article number | 5671475 |
| Pages (from-to) | 263-265 |
| Number of pages | 3 |
| Journal | IEEE Photonics Technology Letters |
| Volume | 23 |
| Issue number | 4 |
| DOIs | |
| State | Published - 2011 |
| Externally published | Yes |
Keywords
- Fabry-Pérot resonators
- microwave oscillators
- optical fiber measurements
- optoelectronic devices
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Atomic and Molecular Physics, and Optics
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Optical frequency stability measurement using an etalon-based optoelectronic oscillator'. Together they form a unique fingerprint.Cite this