Thermal resistance measurement across a wick structure using a novel thermosyphon test chamber

Research output: Contribution to journal › Article › peer-review

Abstract

A novel system is developed for measuring the thermal resistance across thin layers of sintered copper wicks of varying porosity. Wicks to be tested are integrated into a passive vertical thermosyphon system, and the resistance is measured for a series of input power levels. The wicks are sintered to a thermally conducting pedestal above a pool of deionized water and heated from below. The apparent thermal resistance across the wick (from the pedestal/wick interface to the vapor space) under the evaporative operating conditions encountered in heat pipes is measured using thermocouples. The apparent thermal resistance across the wick is measured to be as low as 0.01C/W, corresponding to an evaporative heat transfer coefficient of greater than 128,000 W/m2K.

Original languageEnglish (US)
Pages (from-to)143-154
Number of pages12
JournalExperimental Heat Transfer
Volume21
Issue number2
DOIs
StatePublished - Apr 2008
Externally publishedYes

Keywords

  • Heat pipe
  • Sintered copper wick
  • Thermal resistance
  • Thermosyphon

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Instrumentation
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Thermal resistance measurement across a wick structure using a novel thermosyphon test chamber'. Together they form a unique fingerprint.

Cite this