TY - GEN
T1 - Wireless, Battery-Free Implant for Motor Cortex Chronic Stimulation
AU - Benbuk, Abed
AU - Gulick, Daniel
AU - Moniz-Garcia, Diogo
AU - Quinones-Hinojosa, Alfredo
AU - Blain, Jennifer
N1 - Publisher Copyright: © 2025 IEEE.
PY - 2025
Y1 - 2025
N2 - This work presents a safety assessment of the e-dura substitute concept, where a wireless, battery-free implant is integrated onto a biocompatible, FDA-approved (U.S. Food and Drug Administration) collagen dura substitute for delivering cortical stimulation without contacting the brain surface. The device operates by responding to On-Off-Keying (OOK) modulation of a wireless signal, and it generates voltage pulses, while relaying an optical signal as feedback for post-surgery tracking of device operation. The implant's long-term performance was assessed by submerging the device in saline at human body temperature for eight weeks, and the results show that the output voltage remained at 76.5% of the initial value before the test when using a biocompatible silicone adhesive as the outer encapsulation. Continuous stimulation was delivered for 5 hours in two rats to study the impact of prolonged exposure to wireless stimulation on tissue integrity, and histological analysis was performed to verify tissue integrity post-stimulation. The results reveal no remarkable changes on high and low magnification when comparing the stimulated and non-stimulated hemispheres in two rodents, further confirming the safety of the e-dura method for chronic electrical stimulation treatment.
AB - This work presents a safety assessment of the e-dura substitute concept, where a wireless, battery-free implant is integrated onto a biocompatible, FDA-approved (U.S. Food and Drug Administration) collagen dura substitute for delivering cortical stimulation without contacting the brain surface. The device operates by responding to On-Off-Keying (OOK) modulation of a wireless signal, and it generates voltage pulses, while relaying an optical signal as feedback for post-surgery tracking of device operation. The implant's long-term performance was assessed by submerging the device in saline at human body temperature for eight weeks, and the results show that the output voltage remained at 76.5% of the initial value before the test when using a biocompatible silicone adhesive as the outer encapsulation. Continuous stimulation was delivered for 5 hours in two rats to study the impact of prolonged exposure to wireless stimulation on tissue integrity, and histological analysis was performed to verify tissue integrity post-stimulation. The results reveal no remarkable changes on high and low magnification when comparing the stimulated and non-stimulated hemispheres in two rodents, further confirming the safety of the e-dura method for chronic electrical stimulation treatment.
KW - Cortical
KW - Implant
KW - In Vivo
KW - Stimulation
KW - Wireless
UR - https://www.scopus.com/pages/publications/105045257151
UR - https://www.scopus.com/pages/publications/105045257151#tab=citedBy
U2 - 10.1109/NER61569.2025.11589032
DO - 10.1109/NER61569.2025.11589032
M3 - Conference contribution
T3 - International IEEE/EMBS Conference on Neural Engineering, NER
SP - 1044
EP - 1049
BT - 2025 12th International IEEE/EMBS Conference on Neural Engineering, NER 2025 - Proceedings
PB - IEEE Computer Society
T2 - 12th Annual International IEEE/EMBS Conference on Neural Engineering, NER 2025
Y2 - 11 November 2025 through 14 November 2025
ER -